Imagination. Possibilities. Opportunities.
Starter Lighting Ignition (SLI) Battery are a type of rechargeable battery used in automotive applications that are designed to provide a high initial burst of power. This is necessary for starting as well powering the light and other electrical components in the vehicle. Embedded battery pack for use in motorcycle 150cc and 160cc. Compossed of a lithium cell battery with balancer. This battery pack can be customized based on customer requirements such as: 12V3Ah; 12V/6Ah
etc.
General | |
---|---|
Compliance Information |
Battery Cell: SNI IEC 61960 / SNI IEC 62133 / SNI
IEC 62619 / UL1642 / UL1973 / UL2054 / UL9540A / UN38.1 / UN38.3 /
ROHS
Battery Pack/System: UN38.3 / UN3840 / MSDS
|
Temperature Specification |
Recommended Working Temperature: 10-45°C
Max. Working Temperature: 0-55°C
|
Cell Specification | |
Chemistry | Cell IFR 26650 |
Type | Cylindrical |
Rated Energy | 3.2V 3.6Ah |
Cycle Life of Cell | The cycle life is not less than 2.000 times and the capacity retention rate is ≥80% DOD |
Electrical Parameters | |
Nominal Voltage | 12V |
Nominal Capacity | 6Ah |
Rated Energy | Min. 72 Wh |
Configuration | 4S 2P |
Max. Charge Current | 3A |
Max. Continuous Discharge Current | 18A |
Max. Charging Voltage | 14.6V |
Max. Discharging Voltage | 10V |
Peak Current | 60A |
Battery Dimensions | |
Length | 112 mm |
Width | 69 mm |
Thickness | 106 mm |
Weight | Approx. 0.88 kg |
Casing Material | Plastic Case |
Balancer Features | |
Active Balancing Systems |
Min. working Voltage: 2.0V
Min. Balance Current: 1.2A
|
Safety Features | |
OVP (Over Voltage Protection) | Protection against over charge |
UVP (Under Voltage Protection) | Protection against deep discharge |
OCP (Over Current Protection) | Protection against running overcurrent, which could cause overheating of the protected equipment or circuit. |
Converting a luxury car into a campervan or motorhome generally means changing the cabin in the row behind the driver to install a range of equipment such as a bed, table, kitchen, freezer and others. The motorhome design must be able to accommodate three types of modes, namely driving mode, leisure mode and sleeping mode. The electrical system of a motorhome includes solar panels, batteries, charge controllers, inverters, etc. Embedded battery pack for use as a UPS on a motorhome, consisting of a lithium-cell battery with a battery management system. and other accessories. This battery pack can be customized based on customer requirements such as 12V/100Ah; 12V/150Ah; 12V/200Ah; 12V/400Ah etc.
General | |
---|---|
Compliance Information |
Battery Cell: SNI IEC 61960 / SNI IEC 62133 / SNI
IEC 62619 / UL1642 / UL1973 / UL2054 / UL9540A / UN38.1 / UN38.3 /
ROHS
Battery Pack/System: UN38.3 / UN3840 / MSDS
|
Temperature Specification |
Recommended Working Temperature: 10-45°C
Max. Working Temperature: 0-55°C
|
Cell Specification | |
Chemistry | Cell IFR 26650 |
Type | Cylindrical |
Rated Energy | 3.2V 3.6Ah |
Cycle Life of Cell | The cycle life is not less than 2.000 times and the capacity retention rate is ≥80% DOD |
Electrical Parameters | |
Nominal Voltage | 12V |
Nominal Capacity | 400Ah |
Rated Energy | 4.8 kWh |
Configuration | 4S 115P |
Max. Charge Current | 80A |
Max. Continuous Discharge Current | 200A |
Max. Charging Voltage | 14.6V |
Max. Discharging Voltage | 10V |
Peak Current | 200A |
Battery Dimensions | |
Length | 320 mm |
Width | 270 mm |
Thickness | 460 mm |
Weight | Approx. 50 kg |
Casing Material | Metal Case |
Safety Features | |
OVP (Over Voltage Protection) | Protection against over charge |
UVP (Under Voltage Protection) | Protection against deep discharge |
OCP (Over Current Protection) | Protection against running overcurrent, which could cause overheating of the protected equipment or circuit. |
Passive Cell Balancing | Even out to voltage |
Solar street lights (SSL) are raised light sources which are powered by photovoltaic panels generally mounted on the lighting structure or integrated in the pole itself. There are three types, all-in-two SSL with flat solar panels, all-in-two SSL with vertical solar panels, and all-in-one SSL. All-in-one SSLs are the easiest type of PJU-TS to install, as all the necessary components are integrated into one unit. This type of PJU-TS consists of solar panels, batteries, controller and lamp mounted on a pole. The embedded battery pack used for the all-in-one SSL includes lithium battery cells, BMS and other accessories. This battery pack can be customised based on customer requirements such as 12V/20Ah; 24V/18Ah; 24V/20Ah; 24V/40Ah; etc.
General | |
---|---|
Compliance Information |
Battery Cell: SNI IEC 61960 / SNI IEC 62133 / SNI
IEC 62619 / UL1642 / UL1973 / UL2054 / UL9540A / UN38.1 / UN38.3 /
ROHS
Battery Pack/System: UN38.3 / UN3840 / MSDS
|
Temperature Specification |
Recommended Working Temperature: 10-45°C
Max. Working Temperature: 0-55°C
|
Cell Specification | |
Chemistry | Cell IFP 2265146 |
Type | Prismatic |
Rated Energy | 3.2V 21Ah |
Cycle Life of Cell | The cycle life is not less than 2.000 times and the capacity retention rate is ≥80% DOD |
Electrical Parameters | |
Nominal Voltage | 24V |
Nominal Capacity | 20Ah |
Rated Energy | 480 Wh |
Configuration | 8S 1P |
Max. Charge Current | 20A |
Max. Continuous Discharge Current | 20A |
Max. Charging Voltage | 29.2V |
Max. Discharging Voltage | 20V |
Peak Current | 35A |
Battery Dimensions | |
Length | 281 mm |
Width | 153 mm |
Thickness | 55.5 mm |
Weight | Approx. 4 kg |
Casing Material | PVC Shrink |
Safety Features | |
OVP (Over Voltage Protection) | Protection against over charge |
UVP (Under Voltage Protection) | Protection against deep discharge |
OCP (Over Current Protection) | Protection against running overcurrent, which could cause overheating of the protected equipment or circuit. |
Passive Cell Balancing | Even out to voltage |
Portable battery pack for base transceiver station (BTS) is a piece of equipment that facilitates wireless communication between user equipment (UE) and a network. Composted of a lithium cell battery with BMS. These battery pack can be customized base on customer requirements such as: 48V/50Ah; 48V100Ah; 48V200Ah; 19.2V/280Ah; etc.
General | |
---|---|
Compliance Information |
Battery Cell: SNI IEC 61960 / SNI IEC 62133 / SNI
IEC 62619 / UL1642 / UL1973 / UL2054 / UL9540A / UN38.1 / UN38.3 /
ROHS
Battery Pack/System: UN38.3 / UN3840 / MSDS
|
Temperature Specification |
Recommended Working Temperature: 10-45°C
Max. Working Temperature: 0-55°C
|
Cell Specification | |
Chemistry | Cell IFP 28148115 |
Type | Prismatic |
Rated Energy | 3.2V 52Ah |
Cycle Life of Cell | ≥2000 times @100% DOD |
Electrical Parameters | |
Nominal Voltage | 48V |
Nominal Capacity | 50Ah |
Rated Energy | 2,4 kWh |
Configuration | 15S 1P |
Max. Charge Current | 50A |
Max. Continuous Discharge Current | 50A |
Max. Charging Voltage | 54.75V |
Max. Discharging Voltage | 37.5V |
Peak Current | 100A |
Battery Dimensions | |
Length | 483 mm |
Width | 410 mm 3U |
Thickness | 133 mm |
Weight | Approx. 25 kg |
Casing Material | Metal Case |
Safety Features | |
OVP (Over Voltage Protection) | Protection against over charge |
UVP (Under Voltage Protection) | Protection against deep discharge |
OTC (Over Temperature in Charge) | Protection against overheating while charging |
OTD (Over Temperature in Discharge) | Protection against overheating during discharging |
OCP (Over Current Protection) | Protection against running overcurrent, which could cause overheating of the protected equipment or circuit. |
Passive Cell Balancing | Even out to voltage |
Motorcycle conversion is a government programs to change the motorcycle fuel that is already owned by the community into an electric motorcycle. Moveable battery packs for use in motorcycle conversion as a solution to accelerate programs to reduce air pollution in Indonesia. Compossed of a lithium cell battery with a battery management system. This battery pack can be customized based on customer requirements such as: 60V/20Ah; 72V/20Ah; 72V/21Ah; etc.
General | |
---|---|
Compliance Information |
Battery Cell: SNI IEC 61960 / SNI IEC 62133 / SNI
IEC 62619 / UL1642 / UL1973 / UL2054 / UL9540A / UN38.1 / UN38.3 /
ROHS
Battery Pack/System: UN38.3 / UN3840 / MSDS
|
Temperature Specification |
Recommended Working Temperature: 10-45°C
Max. Working Temperature: 0-55°C
|
Cell Specification | |
Chemistry | Cell IFR 26650 |
Type | Cylindrical |
Rated Energy | 3.2V 3.6Ah |
Cycle Life of Cell | Cycle Life of Cell The cycle life is not less than 2.000 times and the capacity retention rate is ≥80% DOD |
Electrical Parameters | |
Nominal Voltage | 72V |
Nominal Capacity | 20Ah |
Rated Energy | 1,4 kWh |
Configuration | 23S 6P |
Max. Charge Current | 10A |
Max. Continuous Discharge Current | 10A |
Max. Charging Voltage | 83.95V |
Max. Discharging Voltage | 57.5V |
Peak Current | 20A |
Battery Dimensions | |
Length | 380 mm |
Width | 190 mm |
Thickness | 180 mm |
Weight | Approx. 16 kg |
Casing Material | Metal Case |
Safety Features | |
OVP (Over Voltage Protection) | Protection against over charge |
UVP (Under Voltage Protection) | Protection against deep discharge |
OTC (Over Temperature in Charge) | Protection against overheating while charging |
OTD (Over Temperature in Discharge) | Protection against overheating during discharging |
OCP (Over Current Protection) | Protection against running overcurrent, which could cause overheating of the protected equipment or circuit. |
Passive Cell Balancing | Even out to voltage |
Jalan Daan Mogot No.KM. 11, RT.4/RW.8, Kedaung Kali Angke, Cengkareng, West Jakarta City, Jakarta 11710
+62 21 6190708
info@abc-lithium.com